CAUTIONS AND RESTRICTIONS 73
216 FAILED Test: The test detects an error. Take the
replacement of the disk array controller into
account.
√ √
221 NVRAM is corrupt; reinitializing If the error occurs frequently, take the
preventive replacement of the disk array
controller into account.
√
222 NVRAM mismatch occurred If the error occurs frequently, take the
preventive replacement of the disk array
controller into account.
√
223 Link lost on SAS wide port: If the error occurs frequently, take the
preventive replacement of the disk and disk
array controller into account.
√
225
Allowed error rate exceeded on
SAS port:
If the error occurs frequently, take the
preventive replacement of the disk and disk
array controller into account.
√
226
Bad block reassigned: If the error occurs frequently, take the
preventive replacement of the disk into
account.
√
228
Temperature sensor differential
detected on enclosure:
If the error occurs frequently, take the
preventive replacement of the enclosure into
account.
√
229
Disk test cannot start. No
qualifying disks found
If the error occurs frequently, take the
preventive replacement of the disk into
account.
√
230
Time duration provided by host
is not sufficient for self check
If the error occurs frequently, take the
preventive replacement of the disk array
controller into account.
√
235
Firmware download failed on
enclosure:
If the error occurs frequently, take the
preventive replacement of the enclosure into
account.
√
236
Drive is not certified: Check the disk connection.
√
238
PDs missing from configuration
at boot
Check the disk connection.
√
239
VDs missing drives and will go
offline at boot
Check the disk connection.
√
240
VDs missing at boot Check the disk connection.
√
241
Previous configuration
completely missing at boot
Check the disk connection.
√
245
PD rebuild not possible as
SAS/SATA is not supported in
an array
Check whether physical drives to be
supported are used.
√
250
VD is now PARTIALLY
DEGRADED
Partial degrading is detected. Replace the
defected physical drive and run the rebuild
operation.
√
251
VD is now DEGRADED The logical drive is degraded. Replace the
defected physical drive and run the rebuild
operation.
√ √
252
VD is now OFFLINE The logical drive enters into the offline
status. Recover the data by using the
backup.
√ √
254
VD disabled because RAID-5 is
not supported by this RAID key
Please check the RAID key.
√ √
255
VD disabled because RAID-6 is
not supported by this controller
Please check the RAID key.
√ √
256
VD disabled because SAS
drives are not supported by this
RAID key
Please check the SAS driver and the RAID
key.
√ √
257
PD missing Check the disk connection.
√