NEC Express5800/120Li Uživatelská příručka Strana 77

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 77
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 76
CAUTIONS AND RESTRICTIONS 73
216 FAILED Test: The test detects an error. Take the
replacement of the disk array controller into
account.
221 NVRAM is corrupt; reinitializing If the error occurs frequently, take the
preventive replacement of the disk array
controller into account.
222 NVRAM mismatch occurred If the error occurs frequently, take the
preventive replacement of the disk array
controller into account.
223 Link lost on SAS wide port: If the error occurs frequently, take the
preventive replacement of the disk and disk
array controller into account.
225
Allowed error rate exceeded on
SAS port:
If the error occurs frequently, take the
preventive replacement of the disk and disk
array controller into account.
226
Bad block reassigned: If the error occurs frequently, take the
preventive replacement of the disk into
account.
228
Temperature sensor differential
detected on enclosure:
If the error occurs frequently, take the
preventive replacement of the enclosure into
account.
229
Disk test cannot start. No
qualifying disks found
If the error occurs frequently, take the
preventive replacement of the disk into
account.
230
Time duration provided by host
is not sufficient for self check
If the error occurs frequently, take the
preventive replacement of the disk array
controller into account.
235
Firmware download failed on
enclosure:
If the error occurs frequently, take the
preventive replacement of the enclosure into
account.
236
Drive is not certified: Check the disk connection.
238
PDs missing from configuration
at boot
Check the disk connection.
239
VDs missing drives and will go
offline at boot
Check the disk connection.
240
VDs missing at boot Check the disk connection.
241
Previous configuration
completely missing at boot
Check the disk connection.
245
PD rebuild not possible as
SAS/SATA is not supported in
an array
Check whether physical drives to be
supported are used.
250
VD is now PARTIALLY
DEGRADED
Partial degrading is detected. Replace the
defected physical drive and run the rebuild
operation.
251
VD is now DEGRADED The logical drive is degraded. Replace the
defected physical drive and run the rebuild
operation.
252
VD is now OFFLINE The logical drive enters into the offline
status. Recover the data by using the
backup.
254
VD disabled because RAID-5 is
not supported by this RAID key
Please check the RAID key.
255
VD disabled because RAID-6 is
not supported by this controller
Please check the RAID key.
256
VD disabled because SAS
drives are not supported by this
RAID key
Please check the SAS driver and the RAID
key.
257
PD missing Check the disk connection.
Zobrazit stránku 76