CAUTIONS AND RESTRICTIONS 71
102
Rebuild failed due to target
drive error:
The target physical drive may be damaged.
Take the replacement of the physical drive
into account.
√ √
105
Rebuild started: This message is rebuilding starting
notification. The action is unnecessary.
√ √
106
Rebuild automatically started: This message is rebuilding starting
notification. The action is unnecessary.
√ √
107
Rebuild stopped due to loss of
cluster ownership:
Check the authority.
√
108
Reassign write operation failed: If the error occurs frequently, take the
preventive replacement of physical drives
into account.
√ √
109
Unrecoverable medium error
during rebuild:
If the error occurs frequently, take the
preventive replacement of physical drives
into account.
√ √
111
Unrecoverable medium error
during recovery:
If the error occurs frequently, take the
preventive replacement of physical drives
into account.
√ √
119
SAS topology error: Loop
detected
Check the connection of the disk array
controller.
√ √
120
SAS topology error: Device not
addressable
Check whether the disk array controller is
connected correctly.
√ √
121
SAS topology error: Multiple
ports to the same SAS address
Check whether the disk array controller is
connected correctly.
√ √
122
SAS topology error: Expander
error
Check whether the disk array controller is
connected correctly.
√ √
123
SAS topology error: SMP
timeout
Check whether the disk array controller is
connected correctly.
√ √
124
SAS topology error: Out of route
entries
Check whether the disk array controller is
connected correctly.
√ √
125
SAS topology error: Index not
found
Check whether the disk array controller is
connected correctly.
√ √
126
SAS topology error: SMP
function failed
Check whether the disk array controller is
connected correctly.
√ √
127
SAS topology error: SMP CRC
error
Check whether the disk array controller is
connected correctly.
√ √
128
SAS topology error: Multiple
subtractive
Check whether the disk array controller is
connected correctly.
√ √
129
SAS topology error: Table to
table
Check whether the disk array controller is
connected correctly.
√ √
130
SAS topology error: Multiple
paths
Check whether the disk array controller is
connected correctly.
√ √
131
Unable to access device Check whether the disk array controller is
connected correctly.
√ √
134 Dedicated Hot Spare no longer
useful for all arrays:
Take the preventive replacement of physical
drives into account.
√ √
137 Global Hot Spare does not
cover all arrays
Take the preventive replacement of physical
drives into account.
√ √
140 VD Marked inconsistent due to
active writes at shutdown:
Check the consistency for confirmation.
√
145 Battery temperature is high The battery is heated at a high temperature.
If the error occurs frequently, take the battery
replacement into account.
√ √
146 Battery voltage low If the error occurs frequently, take the battery
replacement into account.
√
148 Battery is discharging If the error occurs frequently, take the battery
replacement into account.
150 Battery needs to be replaced,
SOH Bad
Replace the battery.
√ √
154 Battery relearn timed out Replace the battery.
√ √
162 Current capacity of the battery
is below threshold
If the error occurs frequently, take the battery
replacement into account.
√
Komentáře k této Příručce