NEC Express5800/120Li Uživatelská příručka Strana 75

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 77
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 74
CAUTIONS AND RESTRICTIONS 71
102
Rebuild failed due to target
drive error:
The target physical drive may be damaged.
Take the replacement of the physical drive
into account.
105
Rebuild started: This message is rebuilding starting
notification. The action is unnecessary.
106
Rebuild automatically started: This message is rebuilding starting
notification. The action is unnecessary.
107
Rebuild stopped due to loss of
cluster ownership:
Check the authority.
108
Reassign write operation failed: If the error occurs frequently, take the
preventive replacement of physical drives
into account.
109
Unrecoverable medium error
during rebuild:
If the error occurs frequently, take the
preventive replacement of physical drives
into account.
111
Unrecoverable medium error
during recovery:
If the error occurs frequently, take the
preventive replacement of physical drives
into account.
119
SAS topology error: Loop
detected
Check the connection of the disk array
controller.
120
SAS topology error: Device not
addressable
Check whether the disk array controller is
connected correctly.
121
SAS topology error: Multiple
ports to the same SAS address
Check whether the disk array controller is
connected correctly.
122
SAS topology error: Expander
error
Check whether the disk array controller is
connected correctly.
123
SAS topology error: SMP
timeout
Check whether the disk array controller is
connected correctly.
124
SAS topology error: Out of route
entries
Check whether the disk array controller is
connected correctly.
125
SAS topology error: Index not
found
Check whether the disk array controller is
connected correctly.
126
SAS topology error: SMP
function failed
Check whether the disk array controller is
connected correctly.
127
SAS topology error: SMP CRC
error
Check whether the disk array controller is
connected correctly.
128
SAS topology error: Multiple
subtractive
Check whether the disk array controller is
connected correctly.
129
SAS topology error: Table to
table
Check whether the disk array controller is
connected correctly.
130
SAS topology error: Multiple
paths
Check whether the disk array controller is
connected correctly.
131
Unable to access device Check whether the disk array controller is
connected correctly.
134 Dedicated Hot Spare no longer
useful for all arrays:
Take the preventive replacement of physical
drives into account.
137 Global Hot Spare does not
cover all arrays
Take the preventive replacement of physical
drives into account.
140 VD Marked inconsistent due to
active writes at shutdown:
Check the consistency for confirmation.
145 Battery temperature is high The battery is heated at a high temperature.
If the error occurs frequently, take the battery
replacement into account.
146 Battery voltage low If the error occurs frequently, take the battery
replacement into account.
148 Battery is discharging If the error occurs frequently, take the battery
replacement into account.
150 Battery needs to be replaced,
SOH Bad
Replace the battery.
154 Battery relearn timed out Replace the battery.
162 Current capacity of the battery
is below threshold
If the error occurs frequently, take the battery
replacement into account.
Zobrazit stránku 74