72 CAUTIONS AND RESTRICTIONS
166 Communication lost on
enclosure:
Check the connection of the enclosure.
168 Fan failed on enclosure: Check the operation of the enclosure fan.
170 Fan removed on enclosure: Check the connection of the enclosure fan.
171 Power supply failed on
enclosure:
Check the power supply of the enclosure.
177 Temperature sensor below
warning threshold on enclosure:
The temperature sensor exceeds over the
warning threshold. Check the temperature.
178 Temperature sensor below error
threshold on enclosure
The temperature sensor exceeds over the
error threshold. Check the temperature.
179
Temperature sensor above
warning threshold on enclosure
The temperature sensor exceeds over the
warning threshold. Check the temperature.
180
Temperature sensor below error
threshold on enclosure:
The temperature sensor exceeds over the
error threshold. Check the temperature.
181
Enclosure shutdown: Check the enclosure.
182
Too many enclosures
connected to port. Enclosure
not supported:
Decrease the number of connected
enclosures.
183
Firmware mismatch on
enclosure:
The compatibility with the firmware of the
enclosure is disabled. Contact the support
department.
184
Sensor bad on enclosure: Contact the support department.
185
Phy is bad on enclosure: The enclosure may be defected. Take the
replacement into account.
186
Unstable Enclosure: The enclosure may be defected. Take the
replacement into account.
187
Hardware error on enclosure: The enclosure may be defected. Take the
replacement into account.
188
No response from enclosure: The enclosure may be defected. Take the
replacement into account.
189
SAS/SATA mixing not
supported in enclosure;
disabled PD:
SAS and SATA coexist in a specific
enclosure. Check whether the connection is
configured correctly.
190
Unsupported hotplug was
detected on SES enclosure:
The hot-plug is not supported.
195
BBU disabled; changing WB
logical drives to WT
Check the battery.
196
Bad block table is 80% full on
PD:
The bad block table in the physical drive is
filled by 80% or larger. Replace the physical
drive.
197
Bad block table is full; unable to
log block:
The bad block table in the physical drive is
full. Replace the physical drive.
198
Consistency Check Aborted
Due to Ownership Loss on VD:
Check the authority.
199
Background Initialization (BGI)
aborted due to ownership loss
on VD:
Check the authority.
200
Battery/charger problems
detected; SOH Bad
Replace the battery.
201
Single-bit ECC error; warning
threshold exceeded:
Take the preventive replacement of the
physical drive into account.
202
Single-bit ECC error; critical
threshold exceeded:
Replace the physical drive.
203
Single-bit ECC error; further
reporting disabled:
Replace the physical drive.
204 Power supply switched off for
enclosure:
Check the power of the enclosure.
206 Power supply cable removed on
enclosure:
Check whether the power cable of the
enclosure is disconnected.
211 BBU Retention test failed! Replace the BBU.
214 NVRAM Retention test failed! Replace the disk array controller.