72 CAUTIONS AND RESTRICTIONS
166 Communication lost on
enclosure:
Check the connection of the enclosure.
√ √
168 Fan failed on enclosure: Check the operation of the enclosure fan.
√ √
170 Fan removed on enclosure: Check the connection of the enclosure fan.
√ √
171 Power supply failed on
enclosure:
Check the power supply of the enclosure.
√ √
177 Temperature sensor below
warning threshold on enclosure:
The temperature sensor exceeds over the
warning threshold. Check the temperature.
√
178 Temperature sensor below error
threshold on enclosure
The temperature sensor exceeds over the
error threshold. Check the temperature.
√ √
179
Temperature sensor above
warning threshold on enclosure
The temperature sensor exceeds over the
warning threshold. Check the temperature.
√
180
Temperature sensor below error
threshold on enclosure:
The temperature sensor exceeds over the
error threshold. Check the temperature.
√ √
181
Enclosure shutdown: Check the enclosure.
√ √
182
Too many enclosures
connected to port. Enclosure
not supported:
Decrease the number of connected
enclosures.
√
183
Firmware mismatch on
enclosure:
The compatibility with the firmware of the
enclosure is disabled. Contact the support
department.
√ √
184
Sensor bad on enclosure: Contact the support department.
√
185
Phy is bad on enclosure: The enclosure may be defected. Take the
replacement into account.
√ √
186
Unstable Enclosure: The enclosure may be defected. Take the
replacement into account.
√ √
187
Hardware error on enclosure: The enclosure may be defected. Take the
replacement into account.
√ √
188
No response from enclosure: The enclosure may be defected. Take the
replacement into account.
√ √
189
SAS/SATA mixing not
supported in enclosure;
disabled PD:
SAS and SATA coexist in a specific
enclosure. Check whether the connection is
configured correctly.
√
190
Unsupported hotplug was
detected on SES enclosure:
The hot-plug is not supported.
√
195
BBU disabled; changing WB
logical drives to WT
Check the battery.
√
196
Bad block table is 80% full on
PD:
The bad block table in the physical drive is
filled by 80% or larger. Replace the physical
drive.
√ √
197
Bad block table is full; unable to
log block:
The bad block table in the physical drive is
full. Replace the physical drive.
√ √
198
Consistency Check Aborted
Due to Ownership Loss on VD:
Check the authority.
√
199
Background Initialization (BGI)
aborted due to ownership loss
on VD:
Check the authority.
√
200
Battery/charger problems
detected; SOH Bad
Replace the battery.
√ √
201
Single-bit ECC error; warning
threshold exceeded:
Take the preventive replacement of the
physical drive into account.
√ √
202
Single-bit ECC error; critical
threshold exceeded:
Replace the physical drive.
√ √
203
Single-bit ECC error; further
reporting disabled:
Replace the physical drive.
√ √
204 Power supply switched off for
enclosure:
Check the power of the enclosure.
√ √
206 Power supply cable removed on
enclosure:
Check whether the power cable of the
enclosure is disconnected.
√ √
211 BBU Retention test failed! Replace the BBU.
√ √
214 NVRAM Retention test failed! Replace the disk array controller.
√ √
Komentáře k této Příručce