3-4 Linux Setup and Operation
REPLACING 3.5-INCH HARD DISK DRIVE
Follow the procedure below to remove the failed hard disk. If the hard disk fails, it should
be replaced with new device with the server powered-on.
How to Locate Failed Disks
This section describes a procedure to locate failed disks.
1. Open [Data Viewer] from ESMPRO Manager.
If trouble occurs, the color changes from green to red.
In this case, you will notice that there is trouble with both the SCSI Enclosures
(ID: 41) and (ID: 42).
2. Check the SCSI Enclosures (ID: 41) and (ID: 42) on the tree.
See the path information in [General Information] of [SCSI Slot] to locate a
group of 3.5-inch hard disk drive bays that corresponds to each enclosure.
The table below shows the path information on Groups 1 and 2:
Slot
PCI module SCSI adapter SCSI bus
Group1 10 5 0
Group2 11 5 0