4
Event ID
(hex digit)
Severity Description Log Alert Summary Deal Method
0219
(400000DB)
Information [Address Type 1 ] RAID Controller property was changed. RO
0301
(4000012D)
Information [Address Type 2 ] Physical Device is Online. RO M Physical Device Online None
0302
(4000012E)
Information [Address Type 2 ] Physical Device is Ready. RO M Physical Device Ready None
0303
(4000012F)
Information
[Address Type 2 ] Physical Device is Hot Spare.
Physical Device Hot Spare
None
0304
(C0000130)
Fatal [Address Type 2 ] Physical Device is Failed. RO MA Physical Device Failed Please replace the Physical Device.
0305
(80000131)
Warning [Address Type 2 ] Detected S.M.A.R.T. Error. RO MA S.M.A.R.T. Error Please replace the Physical Device.
0306
(40000132)
Information [Address Type 2 ] Rebuild was started. RO MA Rebuild Started None
0307
(40000133)
Information [Address Type 2 ] Rebuild completed. RO MA Rebuild Completed None
0308
(C0000134)
Fatal [Address Type 2 ] Rebuild failed. RO MA Rebuild Failed Please replace the Physical Device.
0309
(40000135)
Information [Address Type 2 ] Rebuild was stopped. RO MA Rebuild Stopped None
0311
(40000137)
Information
[Address Type 2 ] Physical Device was inserted.
Physical Device Inserted
None
0312
(40000138)
Information [Address Type 2 ] Physical Device was removed. RO M Physical Device Removed None
0313
(40000139)
Information [Address Type 2 ] Global Hot Spare created. R
0314
(4000013A)
Information [Address Type 2 ] Dedicated Hot Spare created. R
0315
(4000013B)
Information [Address Type 2 ] Global Hot Spare removed. R
0316
(4000013C)
Information
[Address Type 2 ] Dedicated Hot Spare removed.
0317
(8000013D)
Warning [Address Type 2 ] A Warning Error happened to Physical
Device. Detail : %1
RO M Physical Device Warning Please check the Physical Device. If some kind of
problem happens to the Physical Device repeatedly,
please replace it.
0318
(C000013E)
Fatal
[Address Type 2 ] A Fatal Error happened to Physical Device.
Detail : %1
Physical Device Fatal
Please replace the Physical Device.
0319
(4000013F)
Information [Address Type 2 ] Medium Error was detected in Physical
Device and corrected. %1
RO MA Physical Device Medium
Error(Correctable)
Please replace the Physical Device if too many errors
are detected on a Physical Device.