Event ID
(hex digit)
Severity Description Log Alert Summary Deal Method
0402
(80000192)
Warning [Address Type 3 ] Logical Drive is Degraded. RO MA Logical Drive Degraded If there is Hot Spare, RAID System will rebuild
automatically. If there is not it, please replace the
Physical Device and rebuild it.
0403
(C0000193)
Fatal [Address Type 3 ] Logical Drive is Offline. RO MA Logical Drive Offline Please replace the Physical Device and remake the
Logical Drive. Next restore the backup data to the
Logical Drive.
0404
(40000194)
Information [Address Type 3 ] Initialization was started. R
0405
(40000195)
Information [Address Type 3 ] Initialization completed. R
0406
(C0000196)
Fatal [Address Type 3 ] Initialization failed. RO MA Initialization Failed Please retry Initialization. If Initialization failed
repeatedly, the RAID System may have some kind of
problem. Please deal with the problem of the RAID
System.
0407
(40000197)
Information [Address Type 3 ] Initialization was stopped. R
0409
(40000199)
Information [Address Type 3 ] Consistency Check was started. R
0410
(4000019A)
Information [Address Type 3 ] Consistency Check completed. R
0411
(C000019B)
Fatal [Address Type 3 ] Consistency Check failed. RO MA Consistency Check Failed Please retry Consistency Check. If Consistency Check
failed repeatedly, the RAID System may have some kind
of problem. Please deal with the problem of the RAID
System.
0412
(4000019C)
Information [Address Type 3 ] Consistency Check was stopped. R
0413
(C000019D)
Fatal [Address Type 3 ] Data Inconsistency was detected in
Logical Drive by Consistency Check and corrected.
RO MA Data Inconsistency Error
Corrected
Please execute Consistency Check again when the load
of the system is low. If the error does not occur on the
second time of Consistency Check, the Physical Device
does not have any problems. If the same error occurs,
please replace the Physical Device for the preventive
maintenance (please be sure to ask NEC customer
service before the replacement to identify which
Physical Device has a failure). After replacing the
Physical Device, restore the backup data to the Logical
Drive.
0415
(4000019F)
Information [Address Type 3 ] Logical Drive was created. R
0416
(400001A0)
Information [Address Type 3 ] Logical Drive was deleted. R
0417
(400001A1)
Information [Address Type 3 ] The Cache Mode of Logical Drive was
changed. (Value : %1)
%1 : Changed value
*1
RO M Cache Mode Changed None
6