21 | NEC DISPLAY WALL CALIBRATOR - USER’S GUIDE
Using the Auto ID function with a LAN daisy-chain
The LAN2 RJ45 (output) of a display must connect to the LAN1 RJ45 (input) on the next display in
a daisy-chain.
Each display must have a unique IP address assigned.
Network hub devices must not be used to create multiple branches of displays along the LAN daisy-
chain. All displays must be connected sequentially.
The LAN2 RJ45 of the last display in the daisy-chain must not be connected back to the network
(do not form a network loop).
Monitor IDs are automatically assigned sequentially starting at Monitor ID 1.
Monitor IDs are assigned based on the physical LAN cable connection order - not the IP address
assignment order.
All displays must be powered on when performing the Auto ID function.
The Auto ID function should only be performed from the rst display in the daisy-chain. Do not
perform Auto ID from displays further along the daisy-chain.
Using DHCP (Dynamic Host Conguration Protocol)
Using DHCP with video wall connected via LAN is not recommended, since the IP address
assigned to each display may change if the entire system is restarted.
The software always uses static IP addresses together with a Monitor ID to individually address
each display. If the IP address changes, then the wrong display location may be unintentionally
accessed.