NEC Express5800/R110f-1E Uživatelský manuál Strana 12

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 25
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 11
12
mkscd
[Overview]
Creates an SSD Cache Drive.
[Format]
raidcmd mkscd -c=<controller> -p=<physicaldevice1> [,<physicaldeviceX>, ... ,<physicaldeviceZ>] [-y]
Command Parameter Description
-c=<controller> Specify the RAID Controller connecting with Physical Devices used for the
SSD Cache Drive.
<controller> : RAID Controller Number
-p=<physicaldevice1>
[,<physicaldeviceX>, ... ,<physicaldeviceZ>]
Specify Physical Devices used to create the SSD Cache Drive.
<physicaldevice1,X,Z> : Physical Device Number
Delimit the physical devices with ",".
[-y]
Creates the SSD Cache Drive immediately without displaying the message
of confirming that the SSD Cache Drive may be created.
[Description]
Creates an SSD Cache Drive by specifying Solid State Drive(s).
Available Physical Devices
Physical Devices with [Device Type] of [HDD(SSD)]
Physical Devices with [Status] of [Ready]
Physical Devices not used at all
Capacity of SSD Cache Drive
Use the entire areas of Physical Devices to create an SSD Cache Drive.
[Condition]
This command can be executed only when CacheCade of Premium Feature is enabled.
This command can be executed only in the Advanced Mode.
Zobrazit stránku 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 24 25

Komentáře k této Příručce

Žádné komentáře