Appendix C : Logs/Events
The lists of log and event, alert messages that Universal RAID Utility logs to RAID Log and OS Log are described in this
section.
[Event Source, Alert Type]
OS event source name: raidsrv
Source Name on NEC ESMPRO Manager (Windows): raidsrv
Source Name on NEC ESMPRO Manager (Linux, VMware): RAIDSRV
Alert Type : URAIDUTL
[Log]
Mark
Description
R Universal RAID Utility logs this event to RAID Log.
O Universal RAID Utility logs this event to OS log.
[Alert]
Mark
Description
M and MA
Universal RAID Utility sends this event to NEC ESMPRO Manager as alert.
[
Address
] description in [Description]
The [ Address ] description is different from the category of event.
Category of Event
Type
Description
RAID Controller
Battery
Flash Backup Unit
1 [CTRL:%1(ID=%2)]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
Physical Device 2 [CTRL:%1(ID=%2) PD:%3(ID=%4) %5%6]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Physical Device
%4 : ID of Physical Device
%5 : Vendor and Model of Physical Device
%6 : Firmware Version of Physical Device
Logical Drive
3
[CTRL:%1(ID=%2) LD:%3(ID=%4)]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Logical Drive
%4 : ID of Logical Drive
Enclosure 4 [CTRL:%1(ID=%2) ENC:%3]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
Power Supply Unit in Enclosure 5 [CTRL:%1(ID=%2) ENC:%3 POW:%4]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
%4 : Number of Power Supply Unit
Fan Unit in Enclosure 6 [CTRL:%1(ID=%2) ENC:%3 FAN:%4]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
%4 : Number of Fan Unit
1
Zobrazit stránku 0
1 2 3 4 5 6 ... 10 11

Shrnutí obsahu

Strany 1 - Appendix C : Logs/Events

Appendix C : Logs/Events The lists of log and event, alert messages that Universal RAID Utility logs to RAID Log and OS Log are described in this se

Strany 2 - [priority, facility]

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0515 (80000203) Warning [Address Type 1 ] The temperature of Flash Backup Unit

Strany 3

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0605 (8000025D) Warning [Address Type 5 ] An error happened to the Power Supp

Strany 4

[priority, facility] The messages of Universal RAID Utility have the following priority and facility on Linux or VMware ESX. kind priority facility

Strany 5

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0201 (400000C9) Information [Address Type 1 ] The buzzer of RAID Controller is

Strany 6

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0218 (C00000DA) Fatal [Address Type 1 ] A Fatal Firmware Error happened to RAI

Strany 7

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0305 (80000131) Warning [Address Type 2 ] Detected S.M.A.R.T. Error. RO MA S.M

Strany 8

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0322 (40000142) Information [Address Type 2 ] Rebuild was resumed. R 0323 (

Strany 9

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0406 (C0000196) Fatal [Address Type 3 ] Initialization failed. RO MA Initializ

Strany 10

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0418 (400001A2) Information [Address Type 3 ] Background Initialization was st

Strany 11

Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0434 (400001B2) Information [Address Type 3 ] Background Initialization was qu

Komentáře k této Příručce

Žádné komentáře