N8800-122F/132F, EXP320J NEC Express5800/320Fd-LR N8800-123F/133F, EXP320K NEC Express5800/320Fd-MR User's Guide (Setup) 4th Edition 10-
The patent numbers for the DVC technology of Avocent US. US Patent Number: 5,732,212/5,937,176/6,633,905/6,681,250/6,701,380 (others patents pending
4-36 Windows Setup 2. Select one target network adapter, right-click on it and select [Properties] from the displayed menu to display the Propertie
Windows Setup 4-37 4. Enter the team name, and click [Next >]. 5. Select the check boxes of the adapters you want to include to the team, a
4-38 Windows Setup 7. Click [Finish]. 8. Start a command prompt, and confirm the physical MAC address of the team adapter with ipconfig /all. 9.
Windows Setup 4-39 10. Select the [Advanced] tab in the Properties window. Select [Locally Administered Address] from the [Settings] list box, a
4-40 Windows Setup Step 7: Set Dual Disk Configuration NEC Express5800/ft series secures data by setting dual disk configuration using “RDR (Rapid D
Windows Setup 4-41 IMPORTANT: To perform this procedure, you need to log on as an administrator or a member of administrator group. RDR can
4-42 Windows Setup 3. Start RDR Utility by goint to [Start] - [All Programs] -[RDR] - [RDR Utility]. IMPORTANT: If the [Disk Condition] of the
Windows Setup 4-43 IMPORTANT: If you set RDR on the disk that includes a system partition or a partition that cannot be unmounted, the message on
4-44 Windows Setup 8. Right-click the Slot 1 of the PCI module 1 from the left pane of RDR Utility, and then click [Add Physical Disk To RDR Virtua
Windows Setup 4-45 10. Check that disk synchronization has been started and the status of the DISK ACCESS LED and RDR Utility display changes a
4-46 Windows Setup Synchronization completed RDR Utility DISK ACCESS LED Condition Status Synchronization source disk Green and blinking Duplex
Windows Setup 4-47 Step 8: Update Software If you use ftServer Control Software UPDATE CD-ROM, see “Installing ftServer Control Software” (page 6
4-48 Windows Setup Step 9: Connect and Configure Options When there are optional PCI boards or peripheral devices to connect to the main unit, pow
Windows Setup 4-49 Step 10: Create Volume For NEC Express5800/ft series, you need to perform mirroring for each disk by the RDR function. If yo
4-50 Windows Setup Step 11: Set Network for NEC ESMPRO Agent NEC ESMPRO Agent is required for continuous operation of the NEC Express5800/ft series.
Windows Setup 4-51 Setup of receiving SNMP packets from specific communities only Change the name of the community receiving SNMP packets from th
4-52 Windows Setup Step 12: Enable OS Boot Monitoring Function Enable the “OS Boot Monitoring” setting which has been switched at “OS Boot Monitorin
Windows Setup 4-53 Step 13: Make Settings for Failure Management Make the following settings beforehand to ensure quick recovery from failure. You wil
4-54 Windows Setup 4. Enter the location, where debug information is to be written, in the text box. When writing debug information under the file
Windows Setup 4-55 + 12MB). If the memory is expanded to larger than 2GB, change Write Debugging Information to [Kernel memory dump] before expan
ii Preface Welcome to the NEC Express5800/ft series. NEC Express5800/ft series is a “fault-tolerant (ft)” server focusing on “high reliability” in ter
4-56 Windows Setup 5. Click [Settings] in the [Performance] box. The [Performance Options] window appears. 6. Click the [Advanced] tab on the
Windows Setup 4-57 7. Click [Change] in the [Virtual memory] box. 8. Change the value set for [Initial Size] in the [Paging file
4-58 Windows Setup Size of the Partition to be Created“ (page 4-6). To be prepared for failure, it is recommended to press the dump button to see
Windows Setup 4-59 Set Dr. Watson Dr. Watson of Windows Server 2003 is a debugger for application errors. When detecting an application error, Dr. Wat
4-60 Windows Setup Install a Network Monitor A network monitor is useful for examining the causes of network failures and taking the countermeasures
Windows Setup 4-61 6. If a message is displayed asking you to insert “Windows Server 2003 R2A Enterprise Edition CD-ROM,” follow the instructions on
4-62 Windows Setup Step 15: Back up System Information The system information includes the current BIOS settings and any specific information for t
Chapter 5 Procedures after Completion of Installation This chapter describes how you install management utilities, how you back up system informatio
5-2 Procedures after Completion of Installation INSTALLING MANAGEMENT UTILITIES The provided “NEC EXPRESSBUILDER” DVD contains “NEC ESMPRO Agent”
Procedures after Completion of Installation 5-3 NEC ESMPRO Agent NEC ESMPRO Agent is automatically installed by executing the “Fault Tolerant Serv
iii About This User’s Guide This User's Guide helps a user to properly setup and use the product. Consult this guide when you set up the product
5-4 Procedures after Completion of Installation Operation Environment NEC ESMPRO Agent can be operated in the hardware and software environments s
Procedures after Completion of Installation 5-5 To change the settings of the SNMP Service: 1. Double-click [Administrative Tool] in [Control Pan
5-6 Procedures after Completion of Installation IMPORTANT: If the community name is changed, the community of NEC ESMPRO Agent is changed and
Procedures after Completion of Installation 5-7 Installation NEC ESMPRO Agent is automatically installed together with the installation or re-inst
5-8 Procedures after Completion of Installation 4. Click [Agent] in the main menu of the NEC ESMPRO setup. TIPS: The available menus vary d
Procedures after Completion of Installation 5-9 7. Enter the path in which NEC ESMPRO Agent is installed and click the [Next] button. The NEC ESM
5-10 Procedures after Completion of Installation Setup of NEC ESMPRO Agent The settings of installed NEC ESMPRO Agent remain unchanged from those
Procedures after Completion of Installation 5-11 Uninstall The uninstallation of NEC ESMPRO Agent is described below. Uninstallation of NEC ESMPR
5-12 Procedures after Completion of Installation NEC ESMPRO Manager Linked with NEC ESMPRO Agent installed in the server, NEC ESMPRO Manager monit
Procedures after Completion of Installation 5-13 CONFIRMING THE ft Server Control Software VERSION The following describes how to check the versio
iv 關於正式文本 使正式文本,是為了確實安裝本裝置,能使用的輔導。進行安裝的時候請利用。使正式文本及另冊的用戶指南請經常放置在實體旁邊無論什麼時候能看。 正式文本,作為所說的關於 Windows 等的操作系統和鍵盤,鼠標的一般的輸入輸出設備等的基本的處理有了充分的知識的用戶對象被記載。 正
5-14 Procedures after Completion of Installation APPLYING Windows Service Pack Notes to apply the Windows Service Pack You should not apply servic
Procedures after Completion of Installation 5-15 Power Schemes (Turn off monitor, Turn off hard disks) Hibernation (enable Hibernation)
5-16 Procedures after Completion of Installation (This page is intentionally left blank.)
Chapter 6 Troubleshooting This chapter describes what to do when files needed to operate the OS are damaged and any trouble occurs on the product.
6-2 Troubleshooting SYSTEM REPAIR If the system cannot be operated by some reason, use Recovery Console to restore the system. However, this method
Troubleshooting 6-3 2. Environment variable “AllowRemovableMedia” setting IMPORTANT: This setting is made on the Windows Server 2003 Recovery Consol
6-4 Troubleshooting Note: HDD : Hard disk (SystemDrive, SystemRoot only) FD : Floppy disk CD : CD-ROM Preparation You need a support disk, “Wi
Troubleshooting 6-5 If you have a computer that runs Windows Server 2003 or Windows 2000/XP/ Vista. You can also create a “Windows Server 2003 OEM-D
6-6 Troubleshooting 2. If you have duplexed the HDDs with the RDR (Rapid Disk Resync) feature, unmount and remove CPU/IO module 1 before starting
Troubleshooting 6-7 Welcome to Setup. This portion of the Setup program prepares Microsoft(R) Windows(R) to run on your computer. - To set up Wind
v Contents Preface...i
6-8 Troubleshooting IMPORTANT: The message shown above does not appear when you have started up the Recovery Console installed on the system. 5.
Troubleshooting 6-9 Updating the System IMPORTANT: NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to upd
6-10 Troubleshooting 2. Remove duplications of all the LANs for both onboard and option boards. When dual LAN is disabled, a setup of LAN wil
Troubleshooting 6-11 (d) The confirmation dialog will be displayed. Click [Yes]. 3. Follow the steps below to update the system. Do not input or
6-12 Troubleshooting IMPORTANT: If the message, “Windows - FT Orphaning A disk that is part of a fault-tolerant volume can no longer be accessed”
Troubleshooting 6-13 Installing ft Server Control Software When you install Windows Server 2003 R2, Enterprise x64 Edition with “Manual Setup,” or r
6-14 Troubleshooting rebooting starts by clicking [OK]. Change this screen to check the message, as the message can hide behind the screen. For usin
Troubleshooting 6-15 TROUBLESHOOTING This section describes what you should do when a trouble occurs in the product. Problems with NEC EXPRESSBUI
6-16 Troubleshooting Problems with Windows Setup Failed to install Windows Server 2003 correctly. Have you checked instructions and information o
Troubleshooting 6-17 Windows can be operated after a setup but each module or PCI board is not duplicated. (Status LED 2 on the CPU/IO module does n
vi UNPACKAGING... 1-20 Accessories...
6-18 Troubleshooting Problems with Express Setup Following message appeared when you tried to install Express Setup to the hard disk drive that has
Troubleshooting 6-19 Problems with NEC ESMPRO Setup A menu which cannot be chosen with a setup main menu. → The available menus vary depending on t
6-20 Troubleshooting Problems with System Repair “Press F6 if you need to install a third party SCSI or RAID driver…” was not displayed and there
Appendix A About Services Information on NEC Express5800/ft series is provided the web at NEC Express5800 Web ASIA PACIFIC http://www.nec.co.jp/expre
N8800-122F/132F, EXP320J NEC Express5800/320Fd-LR N8800-123F/133F, EXP320K NEC Express5800/320Fd-MR User's Guide (Setup) 4th Edition
vii Step 6: Set Duplex LAN Configuration...4-31 Overview...
viii Installing ft Server Control Software ... 6-13 TROUBLESHOOTING ...
Chapter 1 Before Using This chapter includes information necessary for proper and safe operation of the server, the main unit and its accessories. Go
PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs and related materials, is the valuable
1-2 Before Using 在使用前 為了把本裝置做為安全確實變成使用必要的關於信息,實體及附屬品等記載著。在安裝實體之前,必定請讀。同時,關於本文中的名稱請參照用戶指南的「與各部分的名稱功能」的項
Before Using 1-3 NOTES FOR SAFE HANDLING The following section describes necessary information to use the product properly and safely. Warning Label
1-4 Before Using 為了把有為了安全對待的注 意的本裝置做為安全確實變成使用必要的信息被記載。 關於警告標籤 隱藏實體內的危險性的零部件和那個週邊警告標籤被粘貼。這個是為了請操縱本裝置的時候, 經常在顧客裡(上)認識能考慮的危險性的東西(揭下標籤,請別弄髒)。如果這個標籤沒被粘貼,
Before Using 1-5 PRECAUTIONS FOR SAFETY This section provides precautions for using the server safely. Read this section carefully to ensure proper a
1-6 Before Using Use of Power Supply and Power Cord WARNING Do not handle power plugs with a wet hand. Do not plug/unplug power cords with a w
Before Using 1-7 Installation, Relocation, Storage and Connection CAUTION Do not install the server in an unsuitable place. Install the serve
1-8 Before Using Cleaning and Handling of Internal Devices WARNING Do not disassemble, repair, or alter the server. Unless described herein,
Before Using 1-9 CAUTION Protect the unused connectors with the protective cap. The unused power cord connectors are covered with the protecti
1-10 Before Using Rack-mount Model WARNING Do not install the server on a nonconforming rack. Install the server on a 19-inch rack conforming
Before Using 1-11 CAUTION Do not install excessive wiring. To prevent burns, fires, and damage to the server, make sure that the rated load o
Keep this User's Guide handy for quick reference when necessary. Safety Indications To use NEC Express5800 series safely, follow the instructi
1-12 Before Using 安全注意事項 本節講述安全使用本伺服器所需的注意事項。為了您正確安全地使用本伺服器,請仔細閱讀該節內容。符號的相關說明請參考“安全標示(SAFETY INDICATIONS)"說明。 一般注意事項 WARNING 不要用於危及人命和需要高度可靠性的操作
Before Using 1-13 使用電源及電源線注意事項 WARNING 不要用濕手拿電源插頭。 不要用濕手插拔電源插頭。有觸電的危險。 不要把地線連接到煤氣管道上。 請勿將地線連接到煤氣管道上。有導致煤氣爆炸的危險。 CAUTION 不要插入未指定的插座。
1-14 Before Using 3極點用的電源插座以外不使用。 被本裝置添加的電源編碼拿第3大頭針(earth pin)的3極點插頭被裝備。這個插頭,只3極點用的電源插座能使用。使用那個以外的電源插座的話,有觸電的可能。 其他的裝置和用途不使用添加的電源編碼 添加的電源編碼作為目的
Before Using 1-15 安裝,移動,保管及連接注意事項 CAUTION 不要安裝或存放在未指定的場所。 不要將本設備放置在如下場所和本書未指定的場所,有導致火災的危險。 灰塵較多的場所 熱水器旁等濕氣較高的場所 陽光直射的場所 不平穩的場所 不
1-16 Before Using CAUTION 不要使用未指定的信號線。 使用NEC指定的信號線,並在確認連接設備和介面後進行連接。使用未指定信號線或連接錯誤等會造成短路、導致火災。 信號線的操作和連接,須遵守以下注意事項: 不要使用任何損壞的信號線接頭。 不要踩踏信號
Before Using 1-17 整理及操作內部設備時的注意事項 WARNING 不要自行拆卸、修理或改造本伺服器。 除本書記載的情況外,不要進行拆卸、修理、改造。否則,不但可能導致設備不能進行正常運行,還有發生觸電和火災的危險。 不要看光碟機內部。 光碟機使用了雷射,
1-18 Before Using CAUTION 請用保護蓋保護好未使用的介面。 請用保護蓋保護好未使用的電源線介面以防止短路或觸電。從內部設備上拔下電源插頭時,用保護蓋蓋好介面,否則有導致火災或觸電的危險。 操作注意事項 CAUTION 不要在打雷時觸摸機器。 打雷
Before Using 1-19 機架式伺服器的注意事項 CAUTION 不要將設備安裝在未指定的機架上。 請將設備安裝在符合EIA標準的19英寸機架上。一定要將設備安裝在指定的機架上才能使用。否則設備可能無法正常使用,並有可能損壞機器零部件或導致人身傷害。關於合適的機架,請與您的經銷
1-20 Before Using UNPACKAGING This product and various accessories are in the special shipping box. Take them out from the box and check the individu
Before Using 1-21 確認箱子的內容的 本產品和附屬品進入著專用的捆包箱子。從箱子取出各自檢點。捆包箱子和有餘了的附屬品請最後一幕保管。關於附屬品本 關於附屬品本 產品的捆包箱子的其中,對實體以外種種的附屬品進入著。確認參照添加的構成品表全部齊(整)的事,請各自檢查。萬一不足的如果
Symbols and its descriptions used in this User’s Guide and warning labels are as follows: Attention Indicates a risk of an electric shock. Indicate
1-22 Before Using (This page is intentionally left blank.)
Chapter 2 About Operating System This chapter gives essential information on the Windows system supported by the server and how to install it.
2-2 About Operating System INSTALLING Windows Server 2003 x64 Editions/ Windows Server 2003 For installing an operating system on NEC Express5800/ft
About Operating System 2-3 About Windows Server 2003 Use the Express Setup program to install Windows Server 2003. Note the following at installation
2-4 About Operating System (This page is intentionally left blank.)
Chapter 3 Installing Server This chapter describes requirements for using the product properly and safely, the setup procedures to make NEC Express58
3-2 Installing Server INSTALLATION This section describes installation of NEC Express5800/ft series. Rack-mount Model You can mount NEC Express5800/
Installing Server 3-3 WARNING Observe the following precautions to use the server safely. There is a risk of a death or serious injury. For details
3-4 Installing Server Place that is close to some equipment that causes power noises (e.g., sparks caused by power-on/off using a relay). If you m
Installing Server 3-5 Installing the device to the rack (N8140-74/92/93/94/98/99) Install this device to the rack. Installing the device to our comp
Mandatory actions Unplug the server. There is a risk of an electric shock or fire. Indicates a general action to take that is not defined herein. M
3-6 Installing Server ● Checking the place to install Decide the place (height) to install. To keep balance, install it as low as you can on the rac
Installing Server 3-7 TIPS: Core nuts (8 pieces) are not included. Use the core nuts that are attached to the rack. 1. If the rack has front and r
3-8 Installing Server 3. Fix the core nuts to the front side of the rack. Attach them symmetrically (total: 8 core nuts). Fix a cor
Installing Server 3-9 5. Tentatively fasten the washers and plate screws (short) to the 4 places on the front and back sides (total: 8) from the rea
3-10 Installing Server 7. Fasten tightly the 4 round screws on the back side and the 8 plate screws on the side panels (which you fastened tentative
Installing Server 3-11 9. Fasten the levers on the left and right sides with screws. 10. Mount the CPU/IO module 1 in the same way.
3-12 Installing Server Unmounting the device from the rack (N8140-74/92/93/94/98/99) Follow the steps below and unmount the device from the rack. CA
Installing Server 3-13 INSTALLING the Tower Conversion Kit (N8843-002) This section describes how to install the rack-mount model of NEC Express5800
3-14 Installing Server Do not install NEC Express5800/ft series in such places as listed below. Otherwise, the server may malfunction. Place where
Installing Server 3-15 Steps to Install the Rack-mount Model to the Tower Conversion Kit Follow the procedure below to install the devices to the tow
安全注意事項 安全標示 請參考本用戶指南中的指示以安全使用NEC Express5800系列伺服器。 本用戶指南說明了設備何處有危險、危險類型、如何避免危險等。在設備可預計到的危險之處或其附近貼有警告標籤。 用戶指南及警告標籤中,根據危險程度不同,使用“警告"、“注意"等詞,含義如下
3-16 Installing Server 4. Fix the bracket with four washers and countersunk screws (long ones), two at the top and two at the bottom.
Installing Server 3-17 If it becomes rocked and cannot insert any further, push and keep the rock lever to the left as push the device further insid
3-18 Installing Server Connect peripheral devices to NEC Express5800/ft series The server provides connectors for a wide variety of peripheral device
Installing Server 3-19 IMPORTANT: Connection of optional devices In the case of standard configuration, you need to complete setup of the operat
3-20 Installing Server Rotate the stopper clockwise, and insert the power cords to the AC inlets of the power unit. Connect the plug at the other e
Windows Setup 4-1 Chapter 4 Windows Setup This chapter describes procedures such as configuring OS Boot Monitoring function, setting dual LAN configu
4-2 Windows Setup Before starting Setup Read this section before starting setup. This chapter describes two types of setup. Procedures to Install
Windows Setup 4-3 SETUP FLOW 0Step 1 Start the OS reinstallation setup procedure Step 2 Prepare the OS reinstallation setup Step 3 Disab
4-4 Windows Setup Step 1: Procedure to Install and Reinstall OS The following explains OS install and reinstall: IMPORTANT: “Express Setup” dele
Windows Setup 4-5 Microsoft® Windows Server™ 2003 R2 32-bit Enterprise Edition Disk2 (One set consists of two disks.) Windows Server 2003 Se
本書及警告標籤中使用的符號 注意 表示有觸電的危險。 表示有因高溫而負傷的危險。 表示有手指等被夾住的危險。 表示有冒煙或者著火的危險。 表示非特定的一般的提醒警告。 表示有因雷射導致失明的危險。 表示有爆炸的危險。 表示有受傷的危險。 禁止行為 表示非特定的一般禁止。 不
4-6 Windows Setup Size of the Partition to be Created For Windows Server 2003 x64 Editions: The required minimum size of a partition to install the
Windows Setup 4-7 TIPS: The mounted memory size means the total of memory installed on a single CPU/IO module. For example, if memory of 1GB is
4-8 Windows Setup Step 2: Prepare for Express Setup Before starting Express Setup, be sure to do the following. You can set up properly only when yo
Windows Setup 4-9 When the AC power is on (The power cords are plugged into the wall outlet) (1) Confirm the POWER LED of the C
4-10 Windows Setup Step 3: Disable OS Boot Monitoring Function Check whether the power is ON and make settings for properly performing setup for lat
Windows Setup 4-11 3. Press the POWER switch located on the front side of the server. (You can see LEDs lit on this side.) IMPORTAN
4-12 Windows Setup 4. When the message “Press <F2> to enter SETUP” or “Press <F2> to enter SETUP or Press <F12> to boot from Netw
Windows Setup 4-13 5. Move the cursor onto “Server” and select “Server.” The Server menu will be displayed: 6. Move the cursor onto “Monito
4-14 Windows Setup 7. Move the cursor onto “OS Boot Monitoring” and press Enter. Parameters will be displayed. 8. Among the parameters, choose “D
Windows Setup 4-15 9. Press the Esc key to go back to the Server menu, and then move the cursor and select “Exit” to display the Exit menu.
強制行為 請將本設備的電源插頭從伺服器上拔下。有發生火災和觸電的危險。 對非特定的一般使用者的行為進行指示。請按照說明進行操作。 這是CLASS 1 LASER PRODUCT。該標籤貼於系統的內部光碟。 注意: 本產品通過多餘的硬體模組提供硬體容錯性能。但是這並不表示能夠保
4-16 Windows Setup Step 4A : Start Express Setup Set up with the Express Setup functions of NEC EXPRESSBUILDER. “Express Setup” is a setup method f
Windows Setup 4-17 Flow of Setup Procedures The following flow chart illustrates the setup procedures for Express Setup. Loading parameters (
4-18 Windows Setup Setup Procedures Express Setup precedes the setup by selecting or inputting several parameters on the wizard. You can also save
Windows Setup 4-19 5. [Load parameters] steps are displayed. [Load parameters] (1) Select [Do not load parameters]. (2) Click [Next]. NOTE: If
4-20 Windows Setup 7. Enter the setting of a logical drive. [Enter RAID settings] steps are displayed. Retain the default value, and click [Next]
Windows Setup 4-21 You cannot reinstall the system with the existing partition that is upgraded to Dynamic Disk remained. Do not select “Use
4-22 Windows Setup 10. Enter the setting of the network protocol. [Enter Network Protocol] steps are displayed. Retain the default value, and
Windows Setup 4-23 13. Select the installing applications. [Select applications] steps are displayed. Retain the default value, and click [Next
4-24 Windows Setup 15. The Express Setup will start when you click [Perform] in [Start Express setup] step. 16. Remove NEC EXPRESSBUILDER
Windows Setup 4-25 Step 4B: Manual Setup Follow the procedures below to create “OEM-Disk” before starting the OS install. Preparing to Install W
Trademarks and Patents NEC EXPRESSBUILDER, NEC ESMPRO and DianaScope are registered trademarks of NEC Corporation. Microsoft, Windows, Windows Ser
4-26 Windows Setup The procedure is as follows: 1. Prepare one 3.5-inch floppy disk. 2. Start the operating system. 3. Insert the NEC EXPRESSBUI
Windows Setup 4-27 Installing Windows Windows Server 2003 x64 Editions Installation Follow the procedure below to install. 1. Power on the sys
4-28 Windows Setup 5. Press <S> key when the right message appears. The right message appears. 6. Set Windows Server 2003 x6
Windows Setup 4-29 – When there are multiple logical drives, select a partition that you would like to install the OS after the next message
4-30 Windows Setup 1) When the dialog box for confirmation of executing system update appears, click [OK]. The system update will start. Fol
Windows Setup 4-31 the rebooting starts by clicking [OK]. Change this screen to check the message, as the message can hide behind the screen. Fo
4-32 Windows Setup
Windows Setup 4-33 Step 5: Windows Server 2003 Service Pack Installation Installing Windows Server 2003 Service Pack A Service Pack for Windows S
4-34 Windows Setup communicates on the network. Regarding the path redundancy, you need to construct the environment by using the spanning tree not
Windows Setup 4-35 NEC Express5800/ft Series Duplication Rule Be sure to set the duplex configuration in the server. Also, when you set the dupl